SPECIFICATIONS
PERFORMANCE |
|
| CHECK READING: | Check Read/Decode/Transmit Time: 2 seconds with 98% first pass good read rate, 99% second pass good read rate. |
| MICR FONTS SUPPORTED: | E13-B and CMC-7, autodiscrimination |
| INTERFACING: | ST8310-2:
|
| DATA FORMAT: | COMMON MICR DATA FORMAT: Every ST8310 contains a user selectable
table of common MICR data output formats. DATA EDITOR: The output data can be uniquely edited by the ST8310 data editor in order to add or delete characters, including preamble and postamble characters |
| MICR EXCEPTION TABLE: | The parsing rules for non-standard MICR line checks can be added in the field via programming checks, bar code menu, clone memory transfer, another ST8310, or host download. |
| OPTIONS: |
Wall Mount Power Pack Host Interface cables ST8300 wall mounting kit MICR head cleaning checks MICR programming checks PC download program |
MECHANICAL/ELECTRICAL |
|
| DIMENSIONS: |
Height: Width: Depth: Weight: |
4.3 in. (10.9cm) 4.08 in. (10.4cm) 5.75 in. (14.6cm) 1.25 lb. (567g) |
| POWER REQUIREMENTS: | Wall Mount Transformer Options: |
120 VAC/60Hz input and 9VDC output. UL/CSA safety listed 230 VAC/50Hz input and 9VDC output. GS/TUV safety listed 240 VAC/50Hz input and 9VDC output. GS/TUV safety listed |
| Input Voltage: | Regulated +5VDC, +10%, 100mV ripple max, or Regulated or unregulated
+7 to +13.5 VDC, 500 mV ripple max |
| Operating Current: | With motor on: 385mA (typical average) With motor off: 125mA (typical) |
ENVIRONMENTAL |
|
| TEMPERATURE: |
Operating: Storage: |
+32°F to +122°F (0°C to 50°C) 0°F to +140°F (-18°C to 60°C) |
| HUMIDITY: | 95% max, non-condensing |
| ESD PROTECTION: | 8KV discharge w/out degradation in performance 15KV discharge w/out
permanent damage |
| AGENCY APPROVAL: | FCC Class A |
|
|
|